Features:

  • Smaller and over 50% lighter than competitive instruments
  • Water-resistant design in an integral concussion-proof enclosure
  • Continuous LCD shows simultaneous gas concentrations for five gases
  • 0 - 1000 ppm measurement of VOCs (Volatile Organic Compounds)
  • Integral motorized pump option for remote sampling
  • Two power options: AA alkaline or rechargeable hot-swappable battery pack
  • Provides 95 dB alarm tone and two bright wide-angled alarm bars
  • Equipped with internal vibrating alarm for high noise areas
  • Multi-language support in English, French, German, Spanish, and Portuguese
  • Three backlight options: standard- activates in low light (auto), in alarm (auto) and reactivates on-demand; alarm only- activates in alarm conditions and reactivates on-demand; stealth mode
  • Four alarm levels: instantaneous Low and High Alarm for all gases; TWA (time-weighted average) and STEL (short-term exposure limit) for VOCs and toxic gases
  • Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
  • Records TWA, STEL, and maximum exposures to gas and displays readings on command
  • User selectable field options include: PID correction factor, language selection, confidence beep, span level, set TWA/STEL calculation choice, set calibration due date, pass code protection, latching alarm, 'SAFE' display function, stealth mode, and selectable ppm resolution for some gases (e.g. SO2 0.1 ppm)
  • Full function self-test of: sensor, battery and circuit integrity; and audible/visual alarms

 

Supported Gases:

  • H2S - hydrogen sulfide
  • CO - carbon monoxide
  • O2 - oxygen
  • HCN - hydrogen cyanide
  • Cl2 - chlorine
  • ClO2 - chlorine dioxide
  • SO2 - sulfur dioxide
  • O3 - ozone
  • PH3 - phosphine
  • NH3 - ammonia
  • NO2 - nitrogen dioxide
  • LEL combustibles
  • PID - photo ionization

Description

  • GasAlertMicro5 PID portable gas detector allows simultaneous monitoring of up to five atmospheric hazards including volatile organic compounds (VOCs), combustible gas (% LEL), oxygen, and a wide selection of individual electrochemical toxic sensors.
  • Compact, lightweight, and rugged, the GasAlertMicro5 PID activates audible, visual and vibrating alarms in the event of a low, high, TWA or STEL alarm condition. VOCs can present multiple potential threats in the workplace environment.
  • VOCs are characterized by their tendency to evaporate easily at room temperature and include substances such as paint thinners, benzene, solvents, butadiene, toluene, hexane, as well as vapors associated with fuels such as diesel, heating oil, gasoline, kerosene, and jet fuel.
  • The GasAlertMicro5 PID’s integrated photoionization detector (PID) enables sensitive broad spectrum monitoring of volatile organic contaminants. Highly configurable to suit a range of applications, GasAlertMicro5 PID comes as either a diffusion or pumped instrument; with either NiMH rechargeable hot-swappable battery pack or normal alkaline and has optional datalogging capabilities.


Specifications

Gas

Measuring range

Resolution

TWA

STEL

LOW

HIGH

O2

0-30.0%

0.1

N/A

N/A

19.5

22.5

CO

0-999 ppm

1

35

200

35

200

H2S

0-100 ppm

1

10

15

10

15

PH3

0-5.0 ppm

0.1

0.3

1.0

0.3

1.0

SO2

0-100 ppm

0.1

2

5

2

5

NO2

0-99.9 ppm

0.1

2.0

5.0

2.0

5.0

HCN

0-30.0 ppm

0.1

4.7

10.0

4.7

10.0

Cl2

0-50.0 ppm

0.1

0.5

1.0

0.5

1.0

NH3

0-100 ppm

1

25

35

25

50

ClO2

0-1 ppm

0.1

0.1

0.3

0.1

0.3

O3

0-1 ppm

0.1

0.1

0.1

0.1

0.1

PID

0-999 ppm

5.0

50

100

50

100

LEL

0-100% LEL
0-5% v/v

1%

N/A

N/A

10%

20%

  

Auto zero

Yes

Calibration

Automatic

Backlight

Standard Mode: low light (auto); alarm condition (auto); reactivation on demand

Alarm Only Mode

alarm condition (auto); reactivation on demand

Stealth Mode

backlight inactive; audible and visual alarms silenced

Sensor

PID (VOC) 10.6 eV lamp; plug-in, electrochemical cell (toxic and oxygen); catalytic (LEL)

User field options

Confidence beep, set STEL period, force calibration on start-up, enable / disable sensor, pass code protection, latching alarms, span level, passed calibration user-lockout option, “SAFE†display function, stealth mode, fast pump, oxygen auto-cal on start-up, alarm only backlight mode, combustible gas measurement (% LEL or % by volume methane), LCD language option, STEL calculation choice, TWA calculation choice, PID / combustible correction factor options, user-settable calibration gas level, high resolution, clock

Pump

Tubing length up to 100 ft. / 30 m (50 ft. / 15 m standard) with user options

Alarm Indicators

Clearly advises alarm conditions with audible, visual, and vibrator alarms

Visual alarms

Two flashing alarm bars visible from all angles

LCD

indicates gas present and alarm levels encountered

Audible alarm

Typically 95 dB at 1 ft. / 30 cm variable pulsed audible alarm

Vibrator alarm

Pulses warning in gas alarm conditions, or for any status alarms

Status alarms

Low battery, over range, multiple gas / pump and failed or missing sensor

ALARM LEVELS

Instantaneous Low Alarm for all gases; Instantaneous High Alarm for all gases
TWA (time-weighted average) and STEL (short-term exposure limit) for toxics/VOCs

LCD

Continuous, alphanumeric gas readout and status display advises:

Gases monitored

VOCs (PID), H2S, CO, O2, SO2, PH3, NO2, NH3, HCN, Cl2, ClO2, O3 and/or combustibles (0-100% LEL or 0-5.0% methane)

Gas concentration

Simultaneously and continuously displays gas concentration(s) for all sensors (in ppm, % LEL, or % v/v)

Peak (max)/STEL/ TWA ppm or %

Records exposures and displays on demand

Alarm setpoints

Displayed on activation and on demand

Calibration due date

Days remaining on start-up

Clock

Real-time clock setting displayed on start-up

Tests

Full function self-test

Sensor integrity, circuitry, battery and audible/visual alarms on activation

Battery

Continuous

General Specifications

Rugged, composite material; two-shot molded polymer case with integral anti-shock boot

Operating temperature

14 to 104oF / -10 to 40oC VOC (PID); -4 to 122oF / -20 to 50oC other gases

Humidity

0 - 95% RH (non-condensing)

EMI/RFI

Complies with EMC Directive 89/336/EEC

Protection

Highly water resistant and dust proof housing

Battery Options

12 hours on three AA alkaline cells or 10 hours on rechargeable hot-swappable battery pack when equipped with PID, oxygen, combustible and TwinTox (H2S/CO) sensor

Size

5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm

Weight

13.1 oz. / 370 g

Warranty

Full 2-year warranty including all sensors (1 year PID lamp and NH3 sensor)

Datalogger Options

User-downloadable datalogger

Data recorder

All events and occurrences (calibration zero adjustment, calibration span adjustment, gas readings, TWA, STEL, alarm condition, failures detected by the microprocessor).

Sampling rate

Factory set at 5-second intervals and user-settable from 1 to 127-second intervals

Storage

2 months of continuous data at 5 second intervals via 32 MB Flash MMC card (64 MB and 128 MB cards also available); when full, the wrap-around feature replaces oldest data with most recent data