| Nominal size |
25mm |
40mm |
50mm |
80mm |
| Connection |
Rc1 or
25A JIS 10K
RF Flange |
Rc1·1/2 or
40A JIS 10K
RF Flange |
Rc2 or
50A JIS 10K
RF Flange |
80A JIS 10K
RF Flange |
Flow range
[m3/h(normal)] |
2.4 to 36 |
10 to 150 |
30 to 450 |
| Operating temp. range |
0 to 60°C |
| Operating pressure range |
0 to 0.7 MPa (Option: 0 to 0.98 MPa) |
| Accuracy (linearity) * |
±1% of full scale |
| Power supply |
DC-powered |
| Body material |
SCS13A |
| Output |
Analog, pulse |
| Configuration |
Non-explosionproof, indoor use, IP65 |
| Applicable fluids |
City gas (13 A), air, nitrogen
|