Use power |
DC110V ± 10% |
Testable items |
Minimum holding current of Toshiba, Hitachi, Meiden Fuji of electromagnetic holding type and scale test
scale test of the Mitsubishi of machine-held |
Electromagnetic hold graduation test circuit |
Output voltage |
DC5 ~ 115V (continuously variable) constant voltage control |
Output current |
10A (more than the rated capacity constant current control)
10A (30 minute rating) |
Electromagnetic-held holding current test circuit |
Current measurement |
0 ~ 1A (continuously variable) constant current control
as possible to adjust the fixed amount in accordance with the impedance of the * measured load, it is constant current control. |
Machine-held HSCB scale test circuit |
Output voltage |
DC0 ~ 1.6V (continuously variable) constant voltage control |
Output current |
10mA (continuous rating) |
Electromagnetic hold graduation test ammeter |
Measurement range |
0 ~ 10.00A (resolution 0.01A) 7-segment LED |
Measurement accuracy |
± 0.5% rdg ± 5dgt |
Sampling rate |
2.5 times / sec. |
External current meter terminal |
To the measurement section and the series of current meter, and providing an external current meter terminal. |
Electromagnetic-held holding current meter |
Measurement range |
0 ~ 1.000A (resolution 0.01A) 7-segment LED |
Measurement accuracy |
± 0.5% rdg ± 5dgt |
Sampling rate |
2.5 times / sec. |
External current meter terminal |
To the measurement section and the series of current meter, and providing an external current meter terminal. |
Mechanical hold graduation test voltmeter |
Measurement range |
0 ~ 1.999V (resolution 0.001V) 7 segment LCD |
Measurement accuracy |
± 0.5% rdg ± 5dgt |
Sampling rate |
2.5 times / sec. |
External voltmeter terminal |
To the measurement section and the series of voltage meter, provided the external voltage meter terminal. |
External dimensions |
530 (W) × about 300 (D) × about 440 (H) |
weight |
20kg |
accessories |
Power cord, (for external current meter) short bar, manual |