Technical Features
- Operating temperature: Depending on the Tc's type
and on the sheath material (max 400°C for TC type T)
- Accuracy: According to EN 60584-2 class 1 or 2
DIN 43710 class 1 o 2
Ansi Mc.96.1 class SPC o STD
- Protection degree: Minimum IP54
- Electrical connection: M20x1,5
TYPE OF SENSOR
J = TC J (Fe-Co)
K = TC K (Cr-Al)
T = TC T (Cu-Co)
N = TC N ( Nicrosil-Nisil)
REFERENCE STANDARD
A = Ansi Mc96.1
D = DIN 43710
I = EN 60584
NUMBER OF SENSING ELEMENTS
1 = Simple
2 = Double
MEASURING JUNCTION
G = Grounded
U = Isolated
STEM DIAMETER Øg
10 = Ø 1 mm
15 = Ø 1,5 mm
20 = Ø 2 mm
30 = Ø 3 mm
45 = Ø 4,5 mm
60 = Ø 6 mm
80 = Ø 8 mm
ACCURACY
1 = Class 1 (EN - DIN)
2 = Class 2 (EN - DIN)
A = Class SPC (Ansi)
B = Class STD (Ansi)
STEM MATERIAL
B = AISI 316 (Max 600°C)
I = INCONEL 600 (Max 1150°C)
THREAD F
-- = Without threa
GA = 1/8" G.
GB = 1/4" G.
GC = 3/8" G.
GD = 1/2" G