Temperature |
Measurement range |
-10 ~ 80°C |
Accuracy |
±0.2°C (0 ~ 60°C) |
Repeatability |
±0.1°C |
Response time |
< 5sec |
Long term drift |
< 0.05°C/year |
|
Humidity |
Measurement range |
0 ~ 100%RH |
Accuracy * |
±1.8%RH (0 ~ 80%RH) |
Repeatability |
±0.2%RH |
Hysterisis |
< ±1%RH |
Response time |
< 4sec |
Long term drift |
< 0.5%RH /Year |
|
Dew point |
Measurement range |
-40 ~ 60°C |
Accuracy ** |
±4°C (-10 ~ 20°C) |
|
Common Specifications |
Power supply |
8 ~ 28Vdc |
Current consumption |
Max 3mA @24Vdc |
Voltage outputs |
2-channels 0~1Vdc / 0~2.5Vdc / 0~5Vdc / 1~5Vdc
(Output impedance : 100Ω) |
Current outputs |
1-channel 4-20mA
: Humidity range : 0 ~ 100%RH
: Temperature range : -40 ~ 80°C |
Digital outputs |
RS485 2-wire half duplex (Modbus RTU protocol)
RS232 serial output (Modbus RTU protocol) |
Filters |
Plastic grid filter with a built in stainless steel mesh
Plastic grid filter
Plastic grid filter with a built in PTFE membrane
Nickel coated sintered filter |
Materials |
Body : Stainless steel (SUS304)
Filter : Cr coated PC/ABS plastic grid
Cable material : PUR |
Operating temperature |
Temperature: -40 ~ 80°C, (Non condensation) |
Storage temperature |
Temperature: -20 ~ 70°C, Humidity: Below 95%RH |
Dimensions |
93mm x Ø12 |
IP rating |
IP65 |
Weight |
20g |